Private Label, White Label, Wholesale partnerships available - EU, USA and UK - Free shipping from €75

Peptide Calculator in Units: Converting mL to U-100 Syringe Units

How to convert between mL, U-100 syringe units and mg for a reconstituted peptide vial, with a units-to-mL table and worked examples.

Short answer: on a U-100 syringe, 100 units = 1 mL, so 1 unit = 0.01 mL and 10 units = 0.1 mL. To find how much material a reading holds, multiply the vial concentration (mg/mL) by the volume in mL. Example: at 5 mg/mL, 10 units (0.1 mL) holds 0.5 mg and 1 unit holds 50 mcg.

Research use only. This page explains measuring and conversion maths for laboratory work. It recommends no amount and describes no use in people or animals.

U-100 units to mL

Units mL At 2.5 mg/mL At 5 mg/mL At 10 mg/mL
1 0.01 mL 25 mcg 50 mcg 100 mcg
5 0.05 mL 125 mcg 250 mcg 0.5 mg
10 0.1 mL 0.25 mg 0.5 mg 1 mg
20 0.2 mL 0.5 mg 1 mg 2 mg
25 0.25 mL 0.625 mg 1.25 mg 2.5 mg
50 0.5 mL 1.25 mg 2.5 mg 5 mg
100 1 mL 2.5 mg 5 mg 10 mg

The three formulas

  1. Concentration (mg/mL) = mg in the vial ÷ mL of bacteriostatic water added.
  2. mL = units ÷ 100 (U-100 syringe).
  3. Material in a reading = concentration × mL.

The peptide reconstitution calculator does all three and draws the syringe reading for you. For vial-specific tables see the guides for tirzepatide, retatrutide, semaglutide, BPC-157, GHK-Cu, MOTS-c and NAD+.

Syringe sizes and their scales

Syringe Capacity Typical marks
0.3 mL U-100 30 units every 1 unit (some every 0.5)
0.5 mL U-100 50 units every 1 unit
1 mL U-100 100 units every 2 units

Smaller syringes have finer marks, so they are easier to read for small volumes. A 1 mL syringe marked every 2 units cannot reliably show an odd number such as 5 units.

U-40 vs U-100: the classic mistake

U-40 syringes hold 40 units per mL, so one U-40 unit is 0.025 mL, 2.5 times a U-100 unit. Every chart on this site assumes U-100. Reading a U-40 syringe against a U-100 chart gives a volume 2.5 times larger than intended. Check the label on the syringe packaging.

Why units depend on how much water you added

A unit is a volume, not an amount. The same 10-unit reading holds 0.25 mg at 2.5 mg/mL and 1 mg at 10 mg/mL. That’s why every reconstituted vial should be labelled with its concentration, and why the water volume is chosen before the vial is mixed. Measure the water with Herbilabs bacteriostatic water: 10 mL vials, made in the EU, COA for every batch.

FAQ

How many units is 1 mL?

100 units on a U-100 syringe.

How many units is 0.25 mL?

25 units on a U-100 syringe.

How do I convert mg to units?

Divide the mg by the concentration to get mL, then multiply by 100. Example: 0.5 mg at 5 mg/mL = 0.1 mL = 10 units.

For research and laboratory use only. Not for human or veterinary use.

Share your love